MATTER 4.2 Input Data Technology EW7

The table on this page contains MARKAL input data for the MATTER 4.2 model. The MATTER 4.2 model was converted from MUSS to ANSWER format in December 1999.
Information regarding the model input is available from ECN, Dolf Gielen (gielen@ecn.nl). More background on this project can be found in a number of recent publications.

Disclaimer


EW7 : Existing capacity windturbines onshore


SET MEMBERSHIP LIST
All Technologies (TCH+SRCENCP)
Technologies: Conversion (CON)
Technologies: Conversion: Electric, Not District Heat (ELE)
Technologies: Conversion: Centralised (CEN)
Technologies: Conversion: Standard (not BAS/NLM)
Technologies: Conversion: Fixed Capacity Utilisation (XLM)
Technologies: Conversion/Demand/Process: Renewable (RNT)

TIME SERIES DATA                                             1990       2000       2010       2020       2030       2040       2050 
Bound on capacity                                            0.44       0.44       0.001      0.001      0.001      0.001      0.001
  Lower  (gigawatts)
Bound on capacity                                            0.45       0.45       0.002      0.002      0.002      0.002      0.002
  Upper  (gigawatts)
Utilisation for season, time of day                          0.285      0.285      0.285      0.285      0.285      0.285      0.285
  Intermediate Day  (decimal fraction)
Utilisation for season, time of day                          0.211      0.211      0.211      0.211      0.211      0.211      0.211
  Intermediate Night  (decimal fraction)
Utilisation for season, time of day                          0.219      0.219      0.219      0.219      0.219      0.219      0.219
  Summer Day  (decimal fraction)
Utilisation for season, time of day                          0.162      0.162      0.162      0.162      0.162      0.162      0.162
  Summer Night  (decimal fraction)
Utilisation for season, time of day                          0.296      0.296      0.296      0.296      0.296      0.296      0.296
  Winter Day  (decimal fraction)
Utilisation for season, time of day                          0.219      0.219      0.219      0.219      0.219      0.219      0.219
  Winter Night  (decimal fraction)
Annual fixed O&M cost                                        18         18         18         18         18         18         18   
  (1995 EURO(ECU)/gigawatts)
Bound on investment in new capacity                          0.45       9.1        34         38         42         45         45   
  Upper  (gigawatts)
Energy carrier input: conversion technology                  2.5        2.5        2.5        2.5        2.5        2.5        2.5  
  Wind energy [GJ]  (petajoules/petajoules)
Total cost of investment in new capacity                     1140       1140       1140       1140       1140       1140       1140 
  (1995 EURO(ECU)/gigawatts)
Fraction of capacity in peak equations                       0          0          0          0          0          0          0    
  (decimal fraction)
Residual installed capacity                                  0          0          0          0          0          0          0    
  (gigawatts)

TIME INDEPENDENT DATA                                        TID
Units of activity/unit of capacity                           31.536
  (petajoules/gigawatts)
Lifetime of new capacity                                     20
  (number of years)
Electricity output                                           1
  Electricity  (decimal fraction)
Start year                                                   1990
  (calendar year)