Disclaimer


EW4 : Large onshore wind turbine


SET MEMBERSHIP LIST
All Technologies (TCH+SRCENCP)
Technologies: Conversion (CON)
Technologies: Conversion: Electric, Not District Heat (ELE)
Technologies: Conversion: Centralised (CEN)
Technologies: Conversion: Standard (not BAS/NLM)
Technologies: Conversion: Fixed Capacity Utilisation (XLM)
Technologies: Conversion/Demand/Process: Renewable (RNT)

TIME SERIES DATA                                             1990       2000       2010       2020       2030       2040       2050 
Bound on capacity                                                       5.55       20         20         20         20         20   
  Lower  (gigawatts)
Bound on capacity                                                       9.05       43.5       76.6       97.8       110.2      112.1
  Upper  (gigawatts)
Utilisation for season, time of day                          1          0.31       0.31       0.31       0.31       0.31       0.31 
  Intermediate Day  (decimal fraction)
Utilisation for season, time of day                          1          0.23       0.23       0.23       0.23       0.23       0.23 
  Intermediate Night  (decimal fraction)
Utilisation for season, time of day                          1          0.24       0.24       0.24       0.24       0.24       0.24 
  Summer Day  (decimal fraction)
Utilisation for season, time of day                          1          0.176      0.176      0.176      0.176      0.176      0.176
  Summer Night  (decimal fraction)
Utilisation for season, time of day                          1          0.322      0.322      0.322      0.322      0.322      0.322
  Winter Day  (decimal fraction)
Utilisation for season, time of day                          1          0.24       0.24       0.24       0.24       0.24       0.24 
  Winter Night  (decimal fraction)
Annual fixed O&M cost                                        0          18         18         18         18         18         18   
  (1995 EURO(ECU)/gigawatts)
Bound on investment in new capacity                                     9.1        34         38         42         45         45   
  Upper  (gigawatts)
Energy carrier input: conversion technology                  2.5        2.5        2.5        2.5        2.5        2.5        2.5  
  Wind energy [GJ]  (petajoules/petajoules)
Total cost of investment in new capacity                     0          950        810        810        810        810        810  
  (1995 EURO(ECU)/gigawatts)
Fraction of capacity in peak equations                       0          0          0          0          0          0          0    
  (decimal fraction)

TIME INDEPENDENT DATA                                        TID
Units of activity/unit of capacity                           31.536
  (petajoules/gigawatts)
Lifetime of new capacity                                     30
  (number of years)
Electricity output                                           1
  Electricity  (decimal fraction)
Start year                                                   2000
  (calendar year)