SET MEMBERSHIP LIST
All Technologies (TCH+SRCENCP)
Technologies: Conversion (CON)
Technologies: Conversion: Electric, Not District Heat (ELE)
Technologies: Conversion: Centralised (CEN)
Technologies: Conversion: Standard (not BAS/NLM)
Technologies: Conversion: Fixed Capacity Utilisation (XLM)
Technologies: Conversion/Demand/Process: Renewable (RNT)
TIME SERIES DATA 1990 2000 2010 2020 2030 2040 2050
Bound on capacity 0.0001 0.000213 0.000325 0.000438 0.00055 0.000663 0.000
Lower (gigawatts)
Bound on capacity 0.02 0.6 0.6 8.2 76 700 1133.
Upper (gigawatts)
Utilisation for season, time of day 0.1612 0.1612 0.1612 0.1612 0.1612 0.1612 0.161
Intermediate Day (decimal fraction)
Utilisation for season, time of day 0 0 0 0 0 0 0
Intermediate Night (decimal fraction)
Utilisation for season, time of day 0.2456 0.2456 0.2456 0.2456 0.2456 0.2456 0.245
Summer Day (decimal fraction)
Utilisation for season, time of day 0 0 0 0 0 0 0
Summer Night (decimal fraction)
Utilisation for season, time of day 0.0714 0.0714 0.0714 0.0714 0.0714 0.0714 0.071
Winter Day (decimal fraction)
Utilisation for season, time of day 0 0 0 0 0 0 0
Winter Night (decimal fraction)
Annual fixed O&M cost 25 20.5 14.8 11.45 8.1 7.6 7.5
(1995 EURO(ECU)/gigawatts)
Bound on investment in new capacity 0.02 0.3 0.3 4.1 38 356 570.6
Upper (gigawatts)
Energy carrier input: conversion technology 2.5 2.5 2.5 2.5 2.5 2.5 2.5
Solar irradiation [GJ] (petajoules/petajoules)
Total cost of investment in new capacity 7000 5000 1980 1525 1070 930 900
(1995 EURO(ECU)/gigawatts)
Fraction of capacity in peak equations 0 0 0 0 0 0 0
(decimal fraction)
TIME INDEPENDENT DATA TID
Units of activity/unit of capacity 31.536
(petajoules/gigawatts)
Lifetime of new capacity 30
(number of years)
Electricity output 1
Electricity (decimal fraction)
Start year 1990
(calendar year)