MATTER 4.2 Input Data Technology EI3

The table on this page contains MARKAL input data for the MATTER 4.2 model. The MATTER 4.2 model was converted from MUSS to ANSWER format in December 1999.
Information regarding the model input is available from ECN, Dolf Gielen (gielen@ecn.nl). More background on this project can be found in a number of recent publications.

Disclaimer


EI3 : Waste to energy plant (Gibros PEC)


SET MEMBERSHIP LIST
All Technologies (TCH+SRCENCP)
Technologies: Conversion (CON)
Technologies: Conversion: Electric, Not District Heat (ELE)
Technologies: Conversion: Centralised (CEN)
Technologies: Conversion: Standard (not BAS/NLM)
Technologies: Conversion: Fixed Capacity Utilisation (XLM)

TIME SERIES DATA                                             1990       2000       2010       2020       2030       2040       2050 
Bound on capacity                                                       0.0001     0.0001     0.0001     0.0001     0.0001     0.000
  Lower  (gigawatts)
Utilisation for season, time of day                          1          1          1          1          1          1          1    
  Intermediate Day  (decimal fraction)
Utilisation for season, time of day                          1          1          1          1          1          1          1    
  Intermediate Night  (decimal fraction)
Utilisation for season, time of day                          1          1          1          1          1          1          1    
  Summer Day  (decimal fraction)
Utilisation for season, time of day                          1          1          1          1          1          1          1    
  Summer Night  (decimal fraction)
Utilisation for season, time of day                          1          1          1          1          1          1          1    
  Winter Day  (decimal fraction)
Utilisation for season, time of day                          1          1          1          1          1          1          1    
  Winter Night  (decimal fraction)
Annual fixed O&M cost                                        0          230        205        182.5      160        160        160  
  (1995 EURO(ECU)/gigawatts)
Material input: conversion technology                        0          2.857      2.5        2.25       2          2          2    
  SOLID MUNICIPAL WASTE [GJ]  (unit of volume for MVOs/petajoules)
Total cost of investment in new capacity                     0          4600       4100       3675       3250       3250       3250 
  (1995 EURO(ECU)/gigawatts)
Fraction of capacity in peak equations                       1          1          1          1          1          1          1    
  (decimal fraction)
Annual variable O&M cost                                     0          3.65       3.17       2.855      2.54       2.54       2.54 
  (1995 EURO(ECU)/petajoules)

TIME INDEPENDENT DATA                                        TID
Units of activity/unit of capacity                           31.536
  (petajoules/gigawatts)
Lifetime of new capacity                                     25
  (number of years)
Electricity output                                           1
  Electricity  (decimal fraction)
Start year                                                   2000
  (calendar year)