SET MEMBERSHIP LIST
All Technologies (TCH+SRCENCP)
Technologies: Conversion (CON)
Technologies: Conversion: Electric, Not District Heat (ELE)
Technologies: Conversion: Centralised (CEN)
Technologies: Conversion: Standard (not BAS/NLM)
Technologies: Conversion: Fixed Capacity Utilisation (XLM)
TIME SERIES DATA 1990 2000 2010 2020 2030 2040 2050
Bound on capacity 0.0001 0.0001 0.0001 0.0001 0.0001 0.000
Lower (gigawatts)
Utilisation for season, time of day 1 1 1 1 1 1 1
Intermediate Day (decimal fraction)
Utilisation for season, time of day 1 1 1 1 1 1 1
Intermediate Night (decimal fraction)
Utilisation for season, time of day 1 1 1 1 1 1 1
Summer Day (decimal fraction)
Utilisation for season, time of day 1 1 1 1 1 1 1
Summer Night (decimal fraction)
Utilisation for season, time of day 1 1 1 1 1 1 1
Winter Day (decimal fraction)
Utilisation for season, time of day 1 1 1 1 1 1 1
Winter Night (decimal fraction)
Annual fixed O&M cost 0 230 205 182.5 160 160 160
(1995 EURO(ECU)/gigawatts)
Material input: conversion technology 0 2.857 2.5 2.25 2 2 2
SOLID MUNICIPAL WASTE [GJ] (unit of volume for MVOs/petajoules)
Total cost of investment in new capacity 0 4600 4100 3675 3250 3250 3250
(1995 EURO(ECU)/gigawatts)
Fraction of capacity in peak equations 1 1 1 1 1 1 1
(decimal fraction)
Annual variable O&M cost 0 3.65 3.17 2.855 2.54 2.54 2.54
(1995 EURO(ECU)/petajoules)
TIME INDEPENDENT DATA TID
Units of activity/unit of capacity 31.536
(petajoules/gigawatts)
Lifetime of new capacity 25
(number of years)
Electricity output 1
Electricity (decimal fraction)
Start year 2000
(calendar year)