SET MEMBERSHIP LIST
All Technologies (TCH+SRCENCP)
Technologies: Conversion (CON)
Technologies: Conversion: Electric, Not District Heat (ELE)
Technologies: Conversion: Centralised (CEN)
Technologies: Conversion: Standard (not BAS/NLM)
Technologies: Conversion: Fixed Capacity Utilisation (XLM)
Technologies: Conversion/Demand/Process: Renewable (RNT)
TIME SERIES DATA 1990 2000 2010 2020 2030 2040 2050
Bound on capacity 8.22 8.55 8.65 8.75 8.85 8.9 8.9
Lower (gigawatts)
Bound on capacity 8.23 8.6 9.745 10.88 11.59 11.9 11.9
Upper (gigawatts)
Utilisation for season, time of day 0.578 0.578 0.578 0.578 0.578 0.578 0.578
Intermediate Day (decimal fraction)
Utilisation for season, time of day 0.427 0.427 0.427 0.427 0.427 0.427 0.427
Intermediate Night (decimal fraction)
Utilisation for season, time of day 0.445 0.445 0.445 0.445 0.445 0.445 0.445
Summer Day (decimal fraction)
Utilisation for season, time of day 0.329 0.329 0.329 0.329 0.329 0.329 0.329
Summer Night (decimal fraction)
Utilisation for season, time of day 0.6 0.6 0.6 0.6 0.6 0.6 0.6
Winter Day (decimal fraction)
Utilisation for season, time of day 0.445 0.445 0.445 0.445 0.445 0.445 0.445
Winter Night (decimal fraction)
Annual fixed O&M cost 25 25 25 25 25 25 25
(1995 EURO(ECU)/gigawatts)
Energy carrier input: conversion technology 2.5 2.5 2.5 2.5 2.5 2.5 2.5
Hydro energy [GJ] (petajoules/petajoules)
Total cost of investment in new capacity 2850 2850 2850 2850 2850 2850 2850
(1995 EURO(ECU)/gigawatts)
Fraction of capacity in peak equations 1 1 1 1 1 1 1
(decimal fraction)
Residual installed capacity 6.77 5.65 4.3 2.85 1.4 0 0
(gigawatts)
TIME INDEPENDENT DATA TID
Units of activity/unit of capacity 31.536
(petajoules/gigawatts)
Lifetime of new capacity 60
(number of years)
Electricity output 1
Electricity (decimal fraction)
Start year 1990
(calendar year)