SET MEMBERSHIP LIST
All Technologies (TCH+SRCENCP)
Technologies: Conversion (CON)
Technologies: Conversion: Electric, Not District Heat (ELE)
Technologies: Conversion: Decentralised (DCN)
Technologies: Conversion: Standard (not BAS/NLM)
TIME SERIES DATA 1990 2000 2010 2020 2030 2040 2050
Annual availability 0.8 0.8 0.8 0.8 0.8 0.8 0.8
(decimal fraction)
Bound on capacity 7.17 5.17 2.59 1.2955 0.001 0.001 0.001
Lower (gigawatts)
Bound on capacity 7.18 5.18 5.18 3.59 2 1.5025 1.005
Upper (gigawatts)
Annual fixed O&M cost 11 11 11 11 11 11 11
(1995 EURO(ECU)/gigawatts)
Bound on investment in new capacity 0.001 0.001 0.001
Upper (gigawatts)
Energy carrier input: conversion technology 3.23 3.03 3.03 3.03 3.03 3.03 3.03
Gas for electricity generation [GJ] (petajoules/petajoules)
Total cost of investment in new capacity 760 760 760 760 760 760 760
(1995 EURO(ECU)/gigawatts)
Energy carrier output: conversion technology 1.74 1.56 1.56 1.56 1.56 1.56 1.56
High temperature steam [GJ] (petajoules/petajoules)
Fraction of capacity in peak equations 1 1 1 1 1 1 1
(decimal fraction)
Residual installed capacity 2 0 0 0 0 0 0
(gigawatts)
Annual variable O&M cost 0.5 0.5 0.5 0.5 0.5 0.5 0.5
(1995 EURO(ECU)/petajoules)
TIME INDEPENDENT DATA TID
Fraction of unavailability which is forced outage 1
(decimal fraction)
Units of activity/unit of capacity 31.536
(petajoules/gigawatts)
Lifetime of new capacity 25
(number of years)
Electricity output 1
Electricity (decimal fraction)
Start year 1990
(calendar year)