SET MEMBERSHIP LIST
All Technologies (TCH+SRCENCP)
Technologies: Conversion (CON)
Technologies: Conversion: Electric and District Heat (CPD)
Technologies: Conversion: Centralised (CEN)
Technologies: Conversion: Standard (not BAS/NLM)
TIME SERIES DATA 1990 2000 2010 2020 2030 2040 2050
Annual availability 0.75 0.75 0.75 0.75 0.75 0.75 0.75
(decimal fraction)
Bound on capacity 1.69 1.3 0.001 0.001 0.001 0.001 0.001
Lower (gigawatts)
Bound on capacity 1.7 1.31 0.91 0.456 0.002 0.002 0.002
Upper (gigawatts)
Ratio of electricity lost to heat gained 0.16 0.16 0.16 0.16 0.16 0.16 0.16
Intermediate Day (decimal fraction)
Ratio of electricity lost to heat gained 0.16 0.16 0.16 0.16 0.16 0.16 0.16
Intermediate Night (decimal fraction)
Ratio of electricity lost to heat gained 0.16 0.16 0.16 0.16 0.16 0.16 0.16
Summer Day (decimal fraction)
Ratio of electricity lost to heat gained 0.16 0.16 0.16 0.16 0.16 0.16 0.16
Summer Night (decimal fraction)
Ratio of electricity lost to heat gained 0.16 0.16 0.16 0.16 0.16 0.16 0.16
Winter Day (decimal fraction)
Ratio of electricity lost to heat gained 0.16 0.16 0.16 0.16 0.16 0.16 0.16
Winter Night (decimal fraction)
Electric loss maximum 0.12 0.12 0.12 0.12 0.12 0.12 0.12
(decimal fraction)
Annual fixed O&M cost 10 10 10 10 10 10 10
(1995 EURO(ECU)/gigawatts)
Energy carrier input: conversion technology 2.17 2.085 2 2 2 2 2
Gas for electricity generation [GJ] (petajoules/petajoules)
Total cost of investment in new capacity 670 670 670 670 670 670 670
(1995 EURO(ECU)/gigawatts)
Fraction of capacity in peak equations 1 1 1 1 1 1 1
(decimal fraction)
Residual installed capacity 0.79 0.4 0 0 0 0 0
(gigawatts)
Transmission efficiency of coupled-production technology 0.98 0.98 0.98 0.98 0.98 0.98 0.98
Intermediate Day (decimal fraction)
Transmission efficiency of coupled-production technology 0.98 0.98 0.98 0.98 0.98 0.98 0.98
Intermediate Night (decimal fraction)
Transmission efficiency of coupled-production technology 0.98 0.98 0.98 0.98 0.98 0.98 0.98
Summer Day (decimal fraction)
Transmission efficiency of coupled-production technology 0.98 0.98 0.98 0.98 0.98 0.98 0.98
Summer Night (decimal fraction)
Transmission efficiency of coupled-production technology 0.98 0.98 0.98 0.98 0.98 0.98 0.98
Winter Day (decimal fraction)
Transmission efficiency of coupled-production technology 0.98 0.98 0.98 0.98 0.98 0.98 0.98
Winter Night (decimal fraction)
Annual variable O&M cost 0.45 0.45 0.45 0.45 0.45 0.45 0.45
(1995 EURO(ECU)/petajoules)
TIME INDEPENDENT DATA TID
Fraction of unavailability which is forced outage 1
(decimal fraction)
Units of activity/unit of capacity 31.536
(petajoules/gigawatts)
Lifetime of new capacity 25
(number of years)
Electricity output 1
Electricity (decimal fraction)
District heat output 1
Low-temperature Heat (decimal fraction)
Start year 1990
(calendar year)