MATTER 4.2 Input Data Technology EC4

The table on this page contains MARKAL input data for the MATTER 4.2 model. The MATTER 4.2 model was converted from MUSS to ANSWER format in December 1999.
Information regarding the model input is available from ECN, Dolf Gielen (gielen@ecn.nl). More background on this project can be found in a number of recent publications.

Disclaimer


EC4 : New pulverised coal power plant


SET MEMBERSHIP LIST
All Technologies (TCH+SRCENCP)
Technologies: Conversion (CON)
Technologies: Conversion: Electric and District Heat (CPD)
Technologies: Conversion: Centralised (CEN)
Technologies: Conversion: Base Loaded (BAS)

TIME SERIES DATA                                             1990       2000       2010       2020       2030       2040       2050 
Annual availability                                          0.75       0.75       0.75       0.75       0.75       0.75       0.75 
  (decimal fraction)
Bound on capacity                                                       11.04      11.04      11.04      0.001      0.001      0.001
  Lower  (gigawatts)
Bound on capacity                                                       14.676                                                      
  Upper  (gigawatts)
Ratio of electricity lost to heat gained                     0.16       0.16       0.16       0.16       0.16       0.16       0.16 
  Intermediate Day  (decimal fraction)
Ratio of electricity lost to heat gained                     0.16       0.16       0.16       0.16       0.16       0.16       0.16 
  Intermediate Night  (decimal fraction)
Ratio of electricity lost to heat gained                     0.16       0.16       0.16       0.16       0.16       0.16       0.16 
  Summer Day  (decimal fraction)
Ratio of electricity lost to heat gained                     0.16       0.16       0.16       0.16       0.16       0.16       0.16 
  Summer Night  (decimal fraction)
Ratio of electricity lost to heat gained                     0.16       0.16       0.16       0.16       0.16       0.16       0.16 
  Winter Day  (decimal fraction)
Ratio of electricity lost to heat gained                     0.16       0.16       0.16       0.16       0.16       0.16       0.16 
  Winter Night  (decimal fraction)
Annual delivery cost                                         0.14       0.14       0.14       0.14       0.14       0.14       0.14 
  Coal for electricity generation [GJ]  (1995 EURO(ECU)/petajoules)
Electric loss maximum                                        0.06       0.06       0.06       0.06       0.06       0.06       0.06 
  (decimal fraction)
Annual fixed O&M cost                                        37         37         37         37         37         37         37   
  (1995 EURO(ECU)/gigawatts)
Energy carrier input: conversion technology                  2.22       2.175      2.13       2.105      2.08       2.08       2.08 
  Coal for electricity generation [GJ]  (petajoules/petajoules)
Total cost of investment in new capacity                     1240       1240       1240       1240       1240       1240       1240 
  (1995 EURO(ECU)/gigawatts)
Fraction of capacity in peak equations                       1          1          1          1          1          1          1    
  (decimal fraction)
Transmission efficiency of coupled-production technology     0.98       0.98       0.98       0.98       0.98       0.98       0.98 
  Intermediate Day  (decimal fraction)
Transmission efficiency of coupled-production technology     0          0          0          0          0          0          0    
  Intermediate Night  (decimal fraction)
Transmission efficiency of coupled-production technology     0.98       0.98       0.98       0.98       0.98       0.98       0.98 
  Summer Day  (decimal fraction)
Transmission efficiency of coupled-production technology     0          0          0          0          0          0          0    
  Summer Night  (decimal fraction)
Transmission efficiency of coupled-production technology     0.98       0.98       0.98       0.98       0.98       0.98       0.98 
  Winter Day  (decimal fraction)
Transmission efficiency of coupled-production technology     0          0          0          0          0          0          0    
  Winter Night  (decimal fraction)
Annual variable O&M cost                                     0.26       0.26       0.26       0.26       0.26       0.26       0.26 
  (1995 EURO(ECU)/petajoules)

TIME INDEPENDENT DATA                                        TID
Fraction of unavailability which is forced outage            1
  (decimal fraction)
Units of activity/unit of capacity                           31.536
  (petajoules/gigawatts)
Lifetime of new capacity                                     30
  (number of years)
Electricity output                                           1
  Electricity  (decimal fraction)
District heat output                                         1
  Low-temperature Heat  (decimal fraction)
Start year                                                   2000
  (calendar year)