MATTER 4.2 Input Data Technology BE4

The table on this page contains MARKAL input data for the MATTER 4.2 model. The MATTER 4.2 model was converted from MUSS to ANSWER format in December 1999.
Information regarding the model input is available from ECN, Dolf Gielen (gielen@ecn.nl). More background on this project can be found in a number of recent publications.

Disclaimer


BE4 : Biomass gasifierSOFC


SET MEMBERSHIP LIST
All Technologies (TCH+SRCENCP)
Technologies: Conversion (CON)
Technologies: Conversion: Electric and District Heat (CPD)
Technologies: Conversion: Centralised (CEN)
Technologies: Conversion: Standard (not BAS/NLM)

TIME SERIES DATA                                             1990       2000       2010       2020       2030       2040       2050 
Annual availability                                          1          1          1          1          1          1          1    
  (decimal fraction)
Bound on capacity                                                                  0.0001     0.000217   0.000333   0.00045    0.000
  Lower  (gigawatts)
Bound on capacity                                                                  2          26         50         62.5       75   
  Upper  (gigawatts)
Ratio of electricity lost to heat gained                     0.039      0.039      0.039      0.039      0.039      0.039      0.039
  Intermediate Day  (decimal fraction)
Ratio of electricity lost to heat gained                     0.039      0.039      0.039      0.039      0.039      0.039      0.039
  Intermediate Night  (decimal fraction)
Ratio of electricity lost to heat gained                     0.039      0.039      0.039      0.039      0.039      0.039      0.039
  Summer Day  (decimal fraction)
Ratio of electricity lost to heat gained                     0.039      0.039      0.039      0.039      0.039      0.039      0.039
  Summer Night  (decimal fraction)
Ratio of electricity lost to heat gained                     0.039      0.039      0.039      0.039      0.039      0.039      0.039
  Winter Day  (decimal fraction)
Ratio of electricity lost to heat gained                     0.039      0.039      0.039      0.039      0.039      0.039      0.039
  Winter Night  (decimal fraction)
Annual delivery cost                                         0          0          1          1          1          1          1    
  Energy chips [GJ]  (1995 EURO(ECU)/petajoules)
Electric loss maximum                                        0.026      0.026      0.026      0.026      0.026      0.026      0.026
  (decimal fraction)
Annual fixed O&M cost                                        0          0          260        200        160        160        160  
  (1995 EURO(ECU)/gigawatts)
Energy carrier input: conversion technology                  0          0          2          1.818      1.613      1.613      1.613
  Energy chips [GJ]  (petajoules/petajoules)
Total cost of investment in new capacity                     0          0          2600       2400       1720       1720       1720 
  (1995 EURO(ECU)/gigawatts)
Fraction of capacity in peak equations                       0          0          1          1          1          1          1    
  (decimal fraction)
Transmission efficiency of coupled-production technology     0.98       0.98       0.98       0.98       0.98       0.98       0.98 
  Intermediate Day  (decimal fraction)
Transmission efficiency of coupled-production technology     0.98       0.98       0.98       0.98       0.98       0.98       0.98 
  Intermediate Night  (decimal fraction)
Transmission efficiency of coupled-production technology     0.98       0.98       0.98       0.98       0.98       0.98       0.98 
  Summer Day  (decimal fraction)
Transmission efficiency of coupled-production technology     0.98       0.98       0.98       0.98       0.98       0.98       0.98 
  Summer Night  (decimal fraction)
Transmission efficiency of coupled-production technology     0.98       0.98       0.98       0.98       0.98       0.98       0.98 
  Winter Day  (decimal fraction)
Transmission efficiency of coupled-production technology     0.98       0.98       0.98       0.98       0.98       0.98       0.98 
  Winter Night  (decimal fraction)

TIME INDEPENDENT DATA                                        TID
Fraction of unavailability which is forced outage            0.75
  (decimal fraction)
Units of activity/unit of capacity                           31.536
  (petajoules/gigawatts)
Lifetime of new capacity                                     25
  (number of years)
Electricity output                                           1
  Electricity  (decimal fraction)
District heat output                                         1
  Low-temperature Heat  (decimal fraction)
Start year                                                   2010
  (calendar year)