SET MEMBERSHIP LIST
All Technologies (TCH+SRCENCP)
Technologies: Conversion (CON)
Technologies: Conversion: Electric and District Heat (CPD)
Technologies: Conversion: Centralised (CEN)
Technologies: Conversion: Standard (not BAS/NLM)
TIME SERIES DATA 1990 2000 2010 2020 2030 2040 2050
Annual availability 1 1 1 1 1 1 1
(decimal fraction)
Bound on capacity 0.0001 0.000217 0.000333 0.00045 0.000
Lower (gigawatts)
Bound on capacity 2 26 50 62.5 75
Upper (gigawatts)
Ratio of electricity lost to heat gained 0.039 0.039 0.039 0.039 0.039 0.039 0.039
Intermediate Day (decimal fraction)
Ratio of electricity lost to heat gained 0.039 0.039 0.039 0.039 0.039 0.039 0.039
Intermediate Night (decimal fraction)
Ratio of electricity lost to heat gained 0.039 0.039 0.039 0.039 0.039 0.039 0.039
Summer Day (decimal fraction)
Ratio of electricity lost to heat gained 0.039 0.039 0.039 0.039 0.039 0.039 0.039
Summer Night (decimal fraction)
Ratio of electricity lost to heat gained 0.039 0.039 0.039 0.039 0.039 0.039 0.039
Winter Day (decimal fraction)
Ratio of electricity lost to heat gained 0.039 0.039 0.039 0.039 0.039 0.039 0.039
Winter Night (decimal fraction)
Annual delivery cost 0 0 1 1 1 1 1
Energy chips [GJ] (1995 EURO(ECU)/petajoules)
Electric loss maximum 0.026 0.026 0.026 0.026 0.026 0.026 0.026
(decimal fraction)
Annual fixed O&M cost 0 0 260 200 160 160 160
(1995 EURO(ECU)/gigawatts)
Energy carrier input: conversion technology 0 0 2 1.818 1.613 1.613 1.613
Energy chips [GJ] (petajoules/petajoules)
Total cost of investment in new capacity 0 0 2600 2400 1720 1720 1720
(1995 EURO(ECU)/gigawatts)
Fraction of capacity in peak equations 0 0 1 1 1 1 1
(decimal fraction)
Transmission efficiency of coupled-production technology 0.98 0.98 0.98 0.98 0.98 0.98 0.98
Intermediate Day (decimal fraction)
Transmission efficiency of coupled-production technology 0.98 0.98 0.98 0.98 0.98 0.98 0.98
Intermediate Night (decimal fraction)
Transmission efficiency of coupled-production technology 0.98 0.98 0.98 0.98 0.98 0.98 0.98
Summer Day (decimal fraction)
Transmission efficiency of coupled-production technology 0.98 0.98 0.98 0.98 0.98 0.98 0.98
Summer Night (decimal fraction)
Transmission efficiency of coupled-production technology 0.98 0.98 0.98 0.98 0.98 0.98 0.98
Winter Day (decimal fraction)
Transmission efficiency of coupled-production technology 0.98 0.98 0.98 0.98 0.98 0.98 0.98
Winter Night (decimal fraction)
TIME INDEPENDENT DATA TID
Fraction of unavailability which is forced outage 0.75
(decimal fraction)
Units of activity/unit of capacity 31.536
(petajoules/gigawatts)
Lifetime of new capacity 25
(number of years)
Electricity output 1
Electricity (decimal fraction)
District heat output 1
Low-temperature Heat (decimal fraction)
Start year 2010
(calendar year)